Front Load Clothes Washer Performance compared to old Top Load Machine

Recently I picked up a used LG front load clothes washer at a good price that needed some repairs. You can read about that here. Once I got the machine spinning well without excessive vibration, I decided to run a comparison test of clothes spinning performance. I loaded up a laundry bag with a typical wash for me - two pairs of pants, cycling clothes, underwear and t-shirts. I did a wash with the old machine, and weighed the clothes dry at the start and wet following the final rinse and spin cycle. I then did the same for the new machine. 

The new LG Washing machine and dryer

The old Kenmore top load washing machine

Weighing the laundry using a digital fish scale


                                Dry Weight (kg) Spun Weight (kg) Water Weight (kg)
Top Load Machine                 4.5 kg                     7.4 kg                 2.9 kg
Front Load Machine         4.4 kg                     5.1 kg                 0.7 kg
Difference                                                                         2.2 kg

The difference in performance of the front loading machine spin is vastly superior - 0.7 kg of water left in the load, versus 2.9 kg for the top loading machine. Drying time went down from 59 minutes to 28 minutes. I'll be saving a lot of electricity - we do about 10 loads of laundry a week with the kids. I should be able to see the effect on my utility bills. Will report back in a year. 

Share:

Diagnosing Front Load Clothes Washer Vibration and Replacing Shock Absorbers

I picked up a used front loading washing machine a few weeks ago, and set about to see if I could get it to function properly without vibration. The previous owner indicated that the washing machine jumped around when in the spin cycle, and that the drum spider arm assembly had been recently replaced.

When I got the machine home, I removed the top cover and did a quick inspection. One issue popped out immediately - a detached drum weight which was resting on the door seal. 

Drum weight missing - should be installed on the four posts with screws


Drum weight reinstalled correctly, Soap Dispensor Removed for Access

I removed the entire soap dispensor assembly to give it a good cleaning, it had some black mould growing in the top and rails of the sliding soap tray. With the soap dispensor removed, I had good access to replace the drum weight and access all the fasteners correctly. I also needed to reinstall the door seal clamping wire correctly, it wasn't in place all the way around the door seal. 

Scrubbing clean the soap trays, receiver and cover

With the weight replaced, and the soap trays replaced, I ran some tests to check the level of vibration. I found that the machine was hopping when spinning up and spinning down at a particular frequency, a resonance issue. So the next step would be to replace the shock absorbers underneath the drum.

Dryer front removed for replacement of shock absorbers

While replacing the shock absorbers, I took the time to clean out the pump filter, and dust underneath the drum. 

It was then time to install the washing machine in the laundry room. I purchased a new set of 90 degree washer hoses so that I'd be able to get the machine nice and close to the wall. I zip-tied the drain hose to the drain pipe so that there was no way the drain hose could fall out of the pipe. 

Installing the washer. Magvent to the right. Dryer outlet moved up on the wall. Zip ties retaining drain hose. Insteon controller on the washer plug.

With the new shock absorbers I've solved the vibration problem, and the machine runs reliably now. Excellent upgrade for the laundry room. 






Share:

Laundry Room Reconfiguration and Magvent Installation

Our 30 year old house has a compact but functional laundry room, set up for top loading machines with the dryer on the left and the washing machine on the right. When upgrading to front loading machines, we learned that the front loader doors open to the left. If the machine is placed on the right of the dryer, the door will be in the way when transferring clothes. So - job number one will be to switch the washer and dryer placement. 

The completed installation - Washing machine on the left, dryer on the right

The second issue to be resolved is the location of the dryer vent outlet, the location of the dryer outlet plug, and the ability to get the machines close to the wall. In the current installation, the dryer vent outlet is on the side wall, and the dryer outlet plug is right at baseboard level - which causes the dryer vent and dryer power cable to interfere. This means I can only get the dryer about 5 inches from the wall, and I need a large loop of flexible duct to be able to make the connections with the machine pulled out from the wall before pushing them into place. 

Current installation - side vent outlet and power plug right at floor level

Current installation - Dryer vent interferes with power plug

With the power plug at floor level, it is very difficult to make connections with both machines in the laundry room at the same time. Installation gymnastics include climbing over the machines to get to the space behind the dryer to make or break connections to get the maching into place or removed. So another aspect of the project will be moving the dryer plug up on the wall and converted the current plug outlet box into a junction box. 

To move the dryer installation to the other side, I ran into an interference with the copper water piping running through the floor plate of the wall to the faucets for the washer. With limited access below the floor due to the placement of the furnace, I wasn't able to move the copper piping to be able to center the new dryer vent placement. I also wanted to get rid of the long flexible duct behind the dryer - and when researching this problem online, I found the Magvent dryer vent magnetic coupler. The Magvent comes with two magnetic elements - the outlet, with a magnetic ring and adapter for 4" round duct, and the part that goes on the back of the dryer - a short length of flexible duct with a second magnetic ring. 

Magvent flexible coupler - installs on dryer outlet


Magvent flexible coupler installed and compressed on the dryer

My installation options for the installation of the Magvent were quite limited, with the copper water pipe blocking a perfect centered location for the magvent. I had to offset the Magvent to one side, partially remove a 2x6 wall stud to give space for the duct coupler, and drill a 4 1/2" hole through the floorplate to route the duct through the basement to the rest of the extraction ductwork. 

Before closing the drywall, I created a drywall box within the wall so that the magvent opening would be sealed by drywall all around, to create a fire break and prevent dryer lint accumulation within the wall space. 

Magvent duct installed in-wall, with duct running down through floor plate

The arrangement worked quite well - with the dryer backed into the wall on the right side of the laundry room, the strong magnets in the Magvent made the connection with no issues, and I didn't have to hand upside down over the dryer connecting any 4" round worm clamps. 

Moving the dryer into position to couple the Magvent

With the dryer outlet moved up the wall - this also avoided any connection gymnastics, easy to reach over the dryer to connect and disconnect the dryer. 

Dryer plug moved up the wall, dryer vent moved from left to right

I've very happy with the completed installation, doors open in the correct way for easy transfer of laundry, and I've managed to get rid of a large loop of flexible duct behind the dryer for greater efficiency. I bought the Magvent at Lee Valley Tools online. 

Washing machine on the left, dryer on the right

I have a few other articles on this project:

1. Repairing and replacing the shock absorbers and drum weights on a front loading washer
4. Comparing the efficiency of an old top-load washer with a new front load washer. 

Feel free to ask any questions in the comments section below. 



Share:

Repairing Cargo Latches and Replacing Seals on a 2001 27EXB (28E33B) Glendale Titanium 5th Wheel

We bought this 20 year old RV earlier this year. One item to repair were the cargo latches on the flip-up door next to the bunk beds. The spring action in the latch was weak - so when you depress the release tab, the lever would not spring up to open the latch. You would have to reach under the level with a fingernail and try to pop it up. In addition, the latch seals were completely rotten, allowing water to get into the door can causing the start of some black mould and rusty hardware.

Starting point - seal half gone, weathered latch body

Some exhausting internet research and I managed to find the same latch for sale on an Asian e-commerce site, however, the inside lever which holds the latch closed did not match my latches. I couldn't find an exact match anywhere, so I decided to order the similar latch and attempt to swap the inside levers from my old latches to the new latch body with new springs and lock cylinders. 

New latch with the shorter inner level. Drilling out the rivets holding the inner lever on the latch.

A few weeks later the new latches arrive, and luckily, they are physically similar. I start by disassembling the inner lever on one of the new latches by drilling out the rivets. The rivets are actually part of the inner lever casting - so when I did the same on the old latches I was very careful to remove a minimum amount of material with a twist drill to facilitate reassembly. 

With the rivets drilled out, the inner lever pulls apart from side to side.

It was then straightforward to transfer the inner levers from the old latch onto the new latch with new springs. The dimensions were all accurate, the o-ring seal which keeps water out of the latch mechanism was transferred off the old inner lever to the new inner lever and everything went back together with some gentle tapping and plier pressure. 

Old latch and inner lever - rivets drilled out and separating the two halves

Reassembling the old inner lever on the new latch - the wood protects the finish on the latch when tapping.

With the inner levers swapped, it was simple to reinstall the latches in the cargo door with the new seals provided with the latches:

New latch installed with new seals

Here's a photo of the old seal next to the new seal - this was the better of the two old seals - the other seal had completely disintegrated.

New and old latch seals

Finally - I reached out to the latch vendor, and ordered some spare sets of seals if you just want to replace your seals. Just click on this link to take you to the sales page on eBay.





Share:

A&E Dometic 8500 Awning Repairs on the Glendale Titanium 27EXB

This post is part of the RV project series. In January 2021 we purchased a 2001 Glendale Titanium 27EXB for a good price, which needed a fairly significant amount of work. Check out all the articles here. The first time we opened the awning was on our first weekend camping trip, and we found the following problems. 

A&E Dometic 8500 series awning

Broken spring on one of the support arm lift handles - pin won't engage in the support arm holes

Lift handle removed, the pin is still there, but with a broken spring it won't engage on the support arm holes
Cracked hardware joining the rafter arm to the support arm

Repairs to the broken lift handle was fairly straightforward. Drill out the rivets holding the lift handle to the support arm, and then use the rivet supplied with the Dometic replacement part to reattach the lift handle to the arm. This repair took about 20 minutes from start to finish. While the lift handle was broken, to use the awning, we used a screwdriver inserted into one to the support arm holes to extend the support arm. 

Removing the broken lift handle by drilling out the rivets

Another issue was cracked hardware joining the rafter arms to the main support arms. There is a complicated casting that slides in channels in the main support arm. In my case these castings were cracked and very close to failure. 

Notice the cracks on the left and right of the white metal casting. Ready to fail.

My RV repair shop had the appropriate parts. The first step in the repair is to remove the rafter arm extension which is riveted to this hardware piece from the main support arm. To do this - you need to momentarily lift off the casting at the top of the support arm which supports the awning roller. Important - this casting is under spring tension - when you lift it off it will let off the tension on the spring of the awning if you don't restrain it. I used a set of vice grips to hold onto this casting to keep it from spinning, and I supported the weight of the awning roller on the top rung of an adjustable ladder while performing the repair. The awning needs to be opened in order to remove the rafter arm. 


Vice grips with a piece of plastic protecting the finish of the piece. Ensure the vice grips are securely attached so that spring tension doesn't cause the casting to spin.


Supporting the awning with an adjustable ladder. Here, the rafter arm is being replaced with new hardware.

Replacing the hardware element is fairly straightforward. Drill out the rivet holding the hardware element to the rafter arm, and then replace the part with a new rivet. The trickiest part is forming the head on the new rivet - it's not a pop rivet, so you need to use a ball pien hammer and punch to form the rivet head correctly. 

First step is to drill out the rivet to release the old part

Install the new part and insert the new rivet

This is the rivet head before forming. I used a roll pin punch with a rounded head to splay out the rivet material, once it was in a cone shape, I used the ball end of a ball pien hammer to roll down the rivet material and finish installation.

These are the old parts - note the damage to the part on the right. I replaced both parts since I was at it.

Total time for this hardware repair was about an hour. You need to extend the awning, and finding the method with the vice grips to keep the support arm upper casting from spinning took some time. 

The next issue with the awning was a series of cracks and holes along the top edge where the awning material is exposed to the sun when the awning is rolled up. I simply used a roll of CAMCO clear awning repair tape to fix these cracks and holes. I performed the cleaning stages carefully - first pass with rubber roof cleaning agent did a fantastic job removing dirt and grime and getting the surface quite clean. Then - prior to applying the tape, I used rubbing alcohol to remove any traces of grease which might keep the tape from adhering properly. This tape is very sticky, applies easily. I used a clean cloth to work the tape into the awning fabric for good adhesion. So far, so good. 

Camco clear awning repair tape applied over cracks in the awning fabric

Feel free to ask any questions in the comments section below. 









Share:

Another new project - the COVID pandemic Fifth Wheel RV Recreation Plan - Ford F250 and Glendale Titanium 27EXB

Just when I thought I had enough on my plate, my wife and I decided to finally execute on the RV project we've been thinking about for years. We've rented C class motorhomes a couple of times now - I always liked that when you rent an RV - someone else takes care of winter storage, repairs, license, insurance, and all the rest. The only downside is the availability of a suitable unit that fits your family. The last C class rental we did, the arrangement of the bed didn't fit well with our family and schedule. The kids are too old now to share a bed, so that means one kid is down on the couch in the middle of the RV, and if that kid is a late sleeper, you have a problem when trying to get going in the morning in the kitchen. And so on.... 

The other issue with the C class is that you need to tow a vehicle if you plan on setting up camp and sightseeing - not impossible, lots of people do it, but this is impractical with a rental. 

So - we ended up going with a pre-owned 2012 Ford F250 4x2, and a pre-owned 2001 Glendale Titanium fifth wheel - 27EXB with bunk beds in the back for the kids. We made the purchase in January and are getting things set up and organized for this summer. 

2012 Ford F250 4x2 Gray Metallic with 2001 Glendale Titanium 27EXB

The truck is well suited for towing the RV - full crew cab so everyone has lots of room, and full 8' box for 90 degree turning capability with the fifth wheel. I'm happy with rear wheel drive - we don't plan to use the vehicle too much in the winter, and it has the electronic locking rear differential to put power to both rear wheels when traction is limited. The lack of 4WD saves some weight and complexity. 

I found a used Reese Titan 16K fifth wheel hitch which I installed with new rails. No need for a sliding fifth wheel hitch. Installed this myself on a Saturday, pretty straightforward. 

Installing the universal bed rail kit for the Reese Titan 16k Hitch

There were plenty of used fifth wheel hitches for sale in January - I ended up going with the Titan because of the urethane bushings which help isolate trailer motion from the truck frame. On my initial haul returning home with the fifth wheel, I was really impressed by how quite and stable everything was. Other than the weight, you really don't notice the trailer unless you're on rough pavement. 

Reese Titan 16k Fifth Wheel

The hitch will need a bit of love, the grease fittings were seized, the jaw bushings were ungreased, and there is some rust on the frame to touch up. 

On the trailer - we got it for a good price, however there is some water damage and structural issues to take care of due to a few years of neglect. The RV is booked for the structural / water damage repairs in March, more on that in future posts. 


Share:

Hydro Quebec Flex D Rate - Controlling Clothes Dryer with Insteon EZIO relay

We're just over half the peak demand season in Quebec, so far, so good. Will write up some articles on what I've done so far. On one demand management period a few weeks ago, someone in the house started the clothes dryer, I caught it after it had been running for about 10 minutes. One of the problems with the whole energy management / peak demand implementation is that it is difficult to get everyone in the house on the same page. I understand that at $0.50 per kW-hr - running the dryer for an hour ends up being an expensive proposition. It's harder to get the two 12 year olds in the house to understand. 

LG Clothes Dryer - Cover Off, Control Board back left of the photo. Relay will go close to control board

For avoiding future problems with the dryer, I decided to implement an interrupt to prevent the dryer from starting during a peak demand event. We have an LG dryer with an electronic control board. I didn't want to get into switching the power feed to the dryer - it's a large circuit. I decided to try interrupting the door open switch, effectively putting a second switch (relay) in series with the door open switch. 

Opening the cover of the dryer exposes the wiring and control board. Cut the power before opening the dryer cover for obvious reasons. The wiring diagram was attached to the inside sidewall of the dryer, and still quite legible. 

LG Dryer Wiring Diagram

The dryer switches 120V (one leg of the 240V), and it switches the connection to neutral. When open - it provides the neutral connection for the lamp inside the dryer, causing the lamp to come on. When closed, it provides the neutral connection for the control board. I decided to interrupt the neutral connection to the control board, in a fail safe fashion. My relay will be normally closed on the neutral circuit to the control board, so that if there is no control system, no connection to the relay power - the dryer will function normally. The interrupt feature will require 24VAC from my control system. 

Wiring in the relay with a relay base was quite simple - 4 connections. 

Relay with base installed on a short braket - no interference with top cover

The wire to the control board was a yellow wire according to the wiring diagram - very easy to identify. I simply cut the wire, crimped in two extensions to take the connection over to one of the relays normally closed pair of terminals. I use heat shrink crimp connections for a neat installation.

Connections made on the NC relay terminals - interrupt yellow wire (neutral to control board)

I ran a control wire down into the basement next to the dryer vent line - very easy in my case - and over to an automation panel where I had a pair of existing Smartenit EZIO 4x2 Insteon relays. I just selected one of the relay output terminals, and used 24VAC from the transformer in the cabinet. When going through the dryer case - I was careful to run the cable through a rubber grommet to avoid any shorts in the future, and ensured my cables were well attached to the dryer frame with zip ties. 

I just finished testing the connection. It works perfectly. When interrupted - the electronic control panel stays powered up, all the control lights are illuminated, but when you press the start button, nothing happens. The control board thinks the door is open and won't initiate the drying sequence. All good. This project was surprisingly quick and easy - took about 2 hours in total. Feel free to ask any questions down below. 




Share:

Hydro Quebec Flex D Rate - Peak Demand Project

Hydro Quebec, my provincial electricity utility, is trialing a dynamic pricing model this winter. It hasn't been rolled out to all residential consumers yet, it's in a trial phase. I applied for the trial and was accepted to participate. I figured that dynamic pricing is inevitable with Quebec's push towards electric cars, so I might as well jump in and see how it goes. My home is already extensively automated, so I should be able to come up with protocols to deal with the peak demand events with a minimum of manual intervention.

The base electricity rates in Quebec are tiered. The first 40 kWh per day are charged at 6.08¢/kWh (1st tier). The remaining energy is charged at 9.38¢/kWh (2nd tier).

The "Rate Flex D" is a dynamic rate where electricity is cheaper than the base rate in winter, except during peak demand events, when it’s more expensive. From December 1st to April 31st of the following year, outside of peak demand events, the price of electricity is below the base rate, so you can save money (4.28¢/kWh for the first tier of 40 kWh/day, and 7.36¢/kWh for the 2nd tier). During peak demand events, electricity is billed at a high price (50¢/kWh). The day before a peak demand event, you receive a notification.

I've been through three days of peak demand events so far. In this post, I'll describe some of my preparation, and how things are going so far. 

First, here are some characteristics about my house.

  • Large, two story house with full basement. Electrically heated garage on an elevated concrete slab, with basement space below the slab. 3/4 of the basement is finished, 1/4 is utility space housing the fan coil, most of the zoned ductwork, the electrical entrance, and storage space under the garage;
  • 400A electrical entrance, with three 200A breaker panels. One panel is designed for critical loads and is connected to a generator transfer switch. There was a generator installed at one time at the house, it has since been removed. 
  • Principal heat source is a Carrier Infinity Greenspeed 4 ton heat pump with variable speed indoor fan coil, with three stages of backup electric resistance heating. The heat pump can maintain a constant temperature in the house, without electric backup heating, down to about -14C. Below that temperature, the heat pump needs help. The heat pump thermal efficiency drops to 1 at about -20C, where it no longer is effective.
  • The forced air ductwork is zoned, with a separate zone for each level of the house - basement, main floor and 1st floor. I upgraded the Infinity system to full zone control this year, and can now control the temperatures on each floor independently. 
  • There are supplemental electric resistance heaters in most of the rooms in the basement for comfort. These are controlled by programmable thermostats. Now, since the zone heating upgrade, I haven't bothered turning those circuits on since I can effectively control the basement temperature from the principal heating system. Our offices are in the basement, and with COVID confinement, a comfortable working temperature in the basement was one of the prime drivers to do the zone heating project.
  • I have extensive Insteon control over lighting. Virtually all lighting in the house, on all levels, is controlled by insteon switches and dimmers. 
More to follow in this series on Rate Flex D Peak Demand.....



Share:

Franke Sink Stopper - Leaky Seal Repair

We did a kitchen renovation about 10 years ago, and installed two side-by-side Franke stainless steel sinks. Total cost was substantial. Only three years after installation, the stoppers started leaking - if you filled the kitchen sink with water and walked away, it would be empty in about an hour. I did a bunch of research, and found that you could purchase a replacement rubber seal for the stopper, you could only purchase the entire stopper. Not particularly cost effective. 

Franke 1145 Strainer Assembly - Expensive way to replace the stopper seal

Note how the new seal on the stopper looks

So - I had a close look at the stopper and seal design, to try to determine why the stoppers were leaking. The seal is in the shape of a tee - with the base of the tee set into a groove on the stopper, and the sealing surface protruding perpendicularly from the base of the tee. When the stopper is set in place, the sealing surface is pushed laterally, and causes the base of the tee to rotate. If the seal rotates enough, you get metal to metal contact between the stopper and the drain fitting, and water can escape past the rotated seal. 

Left Stopper - normal seal. Right stopper - seal flipped down and leaking

I researched possible replacement seals - o-rings, or similar shaped seals and didn't find anything that would fit or seal. You can not purchase just the replacement seal from Franke - you can only purchase the entire replacement stopper. 

Seal removed from stopper - not available as a replacement part

Then, I figured maybe there's another way to prevent the failure mode - the rotation of the seal. What if I could add some support for the perpendicular sealing surface, prevent it from rotating. I found that a very small diameter o-ring stretched around the stopper, just above the seal, supports the seal and keeps it from rotating, and allows the sealing surface to do its job. I've had this fix now for over a year, and is completly reliable. 


Large o-rings, small cross section

Simple stretch the o-ring over top of the seal, snug it up against the metal body, and it will prevent the large stock seal from rotating and leaking water.

Look closely - note the o-ring avove the stock seal

Another view - O-ring above the stock seal
Works well. 

Share:

Shop-Vac is going out of business

 You may not have heard, but Shop-Vac is in receivership. This was announced on September 18, 2020, but I only realized it when I needed a part that I accidently discarded after cleaning my large Shop-Vac. I went to their website and found all of their manuals and customer support information was offline. 

I've had one or two Shop-Vacs for as long as I can remember. As soon as I realized that getting a part might be difficult, I went to Canadian Tire and managed to find what I needed, however I was surprised to find the shelves almost bare of Shop-Vacs, parts and accessories. So I picked up a few spare dry pickup bags. 

Shelves are bare of Shop-Vac at my local Canadian Tire
Shelves are almost bare of Shop-Vacs at my local Canadian Tire

This company is an icon, and their components drove standardization in wet/dry pickup vacuums. Knock-offs abound, and accessories tend to be universal fit across brands now. Maybe this is the reason that they're in financial difficulty. Hopefully someone comes in and rescues the brand and the North American manufacturing facilities based in the Eastern United States. 


Share: